DSpace About DSpace Software 日本語
 

GINMU >
01 奈良県立医科大学 >
012 大学院 >
0122 学位請求論文 >
01221 博士論文(医学) >
2017年度 >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10564/3430

Title: Expansion of Stent and Lumen Diameters on Follow-up after Carotid Artery Stenting in Patients with Carotid Artery Stenosis.
Other Titles: 頸動脈狭窄に対する自己拡張型ステント留置後フォローアップ時のステント径と内腔の検討
Authors: Fujimoto, Kenta
Hashimoto, Hiroyuki
Nishiguchi, Mitsuhisa
Inui, Toshitaka
Tani, Naoki
Horiuchi, Kaoru
Chatani, Megumi
Matsuoka, Ryuta
Yaegaki, Takahide
Nakagawa, Ichiro
Nakase, Hiroyuki
Keywords: carotid artery stenting
self-expansion
plaque
Issue Date: Feb-2017
Publisher: The Japanese Society for Neuroendovascular Therapy
Citation: Journal of Neuroendovascular Therapy Vol.11 No.2 p.65-75 (2017 Feb)
Abstract: Purpose: We examined postoperative stent and lumen expansions after carotid artery stenting (CAS) in patients with carotid artery stenosis. Furthermore, we investigated factors influencing the stent and lumen expansions in a follow-up period. Subjects: 134 cases (128 patients) who underwent CAS and performed follow-up cerebral angiography 12 months after CAS were enrolled into this study. The stenosis rate based on the stent and lumen diameters on follow-up angiography as a percentage of that immediately after CAS was evaluated. Results: Both the stent and lumen diameters were significantly dilated 12 months after CAS (p <0.001). There were no significant stent-type-related differences in the stent expansion rate. In the symptomatic stenosis group, this expansion rate was significantly higher than in the asymptomatic stenosis group (p = 0.02). With respect to the presence or absence of a high signal intensity on time of flight (TOF) magnetic resonance (MR) images, the stent expansion rate was significantly higher in the high signal intensity group (p = 0.006). In patients with a plaque/sternocleidomastoid muscle signal intensity ratio of ≥1.50 on plaque images, it was significantly higher than in those with a value of <1.50 (p = 0.006). However, there were no significant differences in the lumen expansion rate among the groups. Conclusion: Both the stent and vascular lumen were dilated 12 months after CAS. Plaque fragility influenced the stent expansion rate; however, there were no significant factor-related differences in the vascular lumen expansion rate.
Description: 博士(医学)・乙第1414号・平成30年3月15日
©2017 The Editorial Committee of Journal of Neuroendovascular Therapy. All rights reserved. This is an open access article distributed under the terms of Creative Commons Attribution License(CC BY-NC-ND 4.0) https://creativecommons.org/licenses/by-nc-nd/4.0/.
URI: http://hdl.handle.net/10564/3430
ISSN: 18824072
Academic Degrees and number: 24601B1413
Degree-granting date: 2018-03-15
Degree name: 博士(医学)
Degree-granting institutions: 奈良県立医科大学
Appears in Collections:2017年度

Files in This Item:

File Description SizeFormat
01乙1414本文の要旨.pdf乙1414本文の要旨1.76 MBAdobe PDFView/Open
02乙1414審査要旨.pdf乙1414審査要旨324.16 kBAdobe PDFView/Open
03乙1414本文.pdf乙1414本文1.82 MBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback