タイトル: Effectiveness of a new gelatin sealant system for dural closure.
著者: Kawai, Hisashi
Nakagawa, Ichiro
Nishimura, Fumihiko
Motoyama, Yasushi
Park, Young-Su
Nakamura, Mitsutoshi
Nakase, Hiroyuki
Suzuki, Shuko
Ikada, Yoshito
キーワード: Cerebrospinal fluid leak
Dural repair
Dural sealant system
Gelatin glue
発行日: 2014年10月
出版者: Maney Pub.
引用: Neurological research Vol.36 No.10 p.866-872(2014.10)
抄録: Objectives:Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage.Methods:The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated.Results:The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P  =  0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P  =  0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P  =  0·005).Discussion:The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.
内容記述: 博士(医学)・甲第634号・平成27年5月28日
© 2015 W. S. Maney & Son Ltd
The definitive version is available at " http://dx.doi.org/10.1179/1743132814Y.0000000342 "
URI: http://hdl.handle.net/10564/3067
ISSN: 01616412
DOI: http://dx.doi.org/10.1179/1743132814Y.0000000342
学位授与番号: 24601A634
学位授与年月日: 2015-05-28
学位名: 博士(医学)
学位授与機関: 奈良県立医科大学
出現コレクション:2015年度

このアイテムのファイル:

ファイル 記述 サイズフォーマット
01_甲634本文の要旨.pdf甲634本文の要旨239.33 kBAdobe PDF見る/開く
02_甲634審査要旨.pdf甲634審査要旨318.07 kBAdobe PDF見る/開く
03_甲634本文.pdf甲634本文6.34 MBAdobe PDF見る/開く

このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。

 

Valid XHTML 1.0! Powered by DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - ご意見をお寄せください