Title: Primary stenting 後に2度の亜急性血栓性閉塞を発症したと考えられる急性心筋梗塞の1例
Other Titles: A CASE IN WHICH REMAINING DISSECTION AFTER STENT IMPLANTATION MAY HAVE PROVOKED TWO OCCURRENCES OF SAT
Authors: 竹田, 育弘
川本, 篤彦
中嶋, 民夫
佐々木, 弥寿延
上村, 史朗
山野, 繁
橋本, 俊雄
土肥, 和紘
Keywords: acute myocardial infarction
primary stenting
subacute thrombosis
Issue Date: 31-Aug-2000
Publisher: 奈良医学会
Citation: Journal of Nara Medical Association Vol.51 No.4 p.238-244
Abstract: A 61-year-old man was admitted to our hospital with an acute myocardial infarction. Emergency coronary angiography revealed complete occlusion in seg. 6 of left anterior descending artery (LAD). Primary PTCA was performed; however, dissection occurred at the site of balloon inflation. Although two Gianturco-Rubin Ⅱ stents were implanted at the sites of dissection, dissection did not disappear. On the 9th hospital day, subacute thrombosis (SAT) occurred in seg. 6. Occluded LAD was revasculized by PTCA, but dissection was present at seg. 6 and seg. 7. Palmaz-Shatz stent was implanted to seg. 6, but dissection in seg. 7 did not disappear. On the 14th hospital day, recurrence of SAT was clinically suspected, and alteplase was administered intravenously. Coronary angiogra- phy performed on the 61st day revealed no significant stenosis in the LAD, but indicated aneurysm formation in seg. 6. Remaining dissection after stent implantation may have provoked two occurrences of SAT in this case.
URI: http://hdl.handle.net/10564/613
ISSN: 13450069
Appears in Collections:Vol.51 No.4

Files in This Item:

File Description SizeFormat
238-244p.Primary_stenting_後に2度の亜急性血栓性閉塞を発症したと考えられる急性心筋梗塞の1例.pdf2.58 MBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback