DSpace About DSpace Software 日本語
 

GINMU >
01 奈良県立医科大学 >
011 医学部 >
0112 紀要 >
01121 Journal of Nara Medical Association >
Vol.50 No.3 >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10564/518

Title: 屈折矯正手術後における角膜形状が眼圧計測におよぼす影響
Other Titles: EFFECT OF CORNEAL CONFIGURATION CHANGE ON MEASUREMENT OF INTRAOCULAR PRESSURE IN LASER KERATOREFRACTIVE SURGERY
Authors: 小南, 雅也
魚里, 博
西信, 元嗣
Keywords: keratorefractive surgery
postoperative IOP measurement
central corneal thickness
central corneal curvature
corneal hydration
Issue Date: 30-Jun-1999
Publisher: 奈良医学会
Citation: Journal of Nara Medical Association Vol.50 No.3 p.220-232
Abstract: Corneal configuration change due to recent keratorefractive surgery such as photorefractive keratectomy (PRK), photherapeutic keratectomy (PTK), and laser in- situ keratomileusis (LASIK) reduce the corneal rigidity, and will result in significant underestimation of postoperative intraocular pressure (IOP) measurement. So we have analyzed the relation between corneal cofiguration change and postoperative measurement of IOP in keratorefractive surgery (PRK PTK, and LASIK). Actual IOP was controlled using a manometer inserted into the anterior chamber of enucleated pig eyes. Clinical IOP was measured with electronic applanation tonometer (Tono-Pen XL, Menter) at several heights of manometer, central corneal thickness (CCT) was measured with ultrasonic pachymeter (SP-2000, Tome.) before and after IOP measure- ment, and anterior corneal curvature with Orbscan (Orbtech). Each measured IOP was analyzed statistically with linear regression and paired t-test. Measured IOP of the group of normal eyeball with various CCT was increased in every experimentation as CCT increased. And measured IOP of automated lamellar keratoplasty (ALK) performed group was significantly reduced as CCT reduced. Linear correlation was established between set up IOP and measured IOP, with correlation coefficients close to unity. Correlation between CCT and the measured IOP, CCT and the difference of the measured IOP to each sample was statistically highly significant (P<0.001). Measured anterior corneal curvature at 3 mm diameter of central cornea of the ALK performed group was decreased as IOP increased. Results of our investigation show that CCT has a larger effect on the measurement of IOP than central corneal curvature and corneal hydration. We should take into consideration the corneal configuration change for proper assessment of postoperative IOP measurement in recent keratorefractive surgery.
URI: http://hdl.handle.net/10564/518
ISSN: 13450069
Appears in Collections:Vol.50 No.3

Files in This Item:

File Description SizeFormat
220-232p.屈折矯正手術後における角膜形状が眼圧計測におよぼす影響.pdf1.35 MBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback