Title: Isometric Contraction of the Quadriceps Improves the Accuracy of Intra-Articular Injections into the Knee Joint via the Superolateral Approach.
Other Titles: 大腿四頭筋の等尺性収縮は、膝蓋上外側アプローチによる膝関節内注射の正確性を向上する
Authors: Wada, Makoto
Fujii, Tadashi
Inagaki, Yusuke
Nagano, Tatsuo
Tanaka, Yasuhito
Issue Date: 23-Oct-2018
Publisher: The Journal of Bone and Joint Surgery, Inc.
Citation: Journal of bone and joint surgery open access Vol.3 No.4 Article No.e0003 (2018 Oct)
Abstract: Background: Intra-articular injection is an important technique for treating rheumatoid arthritis and osteoarthritis of the knee. However, medication is often inaccurately injected outside of the joint. We devised an intra-articular injection method in which the needle is inserted into the suprapatellar bursa while the patient maintains isometric contraction of the quadriceps. This isometric contraction method is based on the concept that isometric contraction of the quadriceps induces contraction of the articularis genus muscle, thus expanding the lumen of the suprapatellar bursa. Methods: Intra-articular injections were performed on 150 osteoarthritic knees without effusion. The knees were alternately assigned to the isometric quadriceps method group (75 knees) and non-activated quadriceps method group (75 knees). Prior to joint injection, the anterior-posterior dimension of each suprapatellar bursa was measured to ascertain its expansion. The isometric quadriceps method was performed with the quadriceps and the articularis genus muscle maintained in a contracted state. The non-activated quadriceps method was performed in a relaxed state. Ultrasound guidance was not used for either method. Subsequently, an ultrasonic probe was used only to confirm whether the intra-articular injections were successful. We compared the accuracy of injections performed between the 2 groups. Results: Suprapatellar expansion was significantly larger (p < 0.001) using the isometric quadriceps method (2.1 ± 1.4 mm [range, 0 to 5 mm]) than using the non-activated quadriceps method (0.8 ± 0.7 mm [range, 0 to 2 mm]). The percentage of accurate intra-articular injections was significantly higher (p = 0.0287) using the isometric quadriceps method (93%) compared with the non-activated quadriceps method (80%). Conclusions: In comparison with the non-activated quadriceps method, the isometric quadriceps method led to a larger expansion of the suprapatellar bursa, which should lead to more accurate intra-articular injections. The isometric quadriceps method is effective in reducing inaccurate injections into the synovium or surrounding fatty tissues. Clinical relevance: Putting force on the quadriceps muscle increases the success rate of intra-articular injection of the knee. The results of this study could provide a clinically relevant injection technique for future treatment.
Description: 博士(医学)・乙第1448号・令和元年12月5日
Copyright © 2018 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND https://creativecommons.org/licenses/by-nc-nd/4.0/), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
URI: http://hdl.handle.net/10564/3704
ISSN: 24727245
DOI: http://dx.doi.org/10.2106/JBJS.OA.18.00003
Academic Degrees and number: 24601B1448
Degree-granting date: 2020-12-05
Degree name: 博士(医学)
Degree-granting institutions: 奈良県立医科大学
Appears in Collections:2019年度

Files in This Item:

File Description SizeFormat
01乙1448本文の要旨.pdf乙1448本文の要旨1.58 MBAdobe PDFView/Open
02乙1448審査要旨.pdf乙1448審査要旨325.53 kBAdobe PDFView/Open
03乙1448本文.pdf乙1448本文467.24 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback