Title: Biomechanical study of distal radioulnar joint ballottement test.
Other Titles: 遠位橈尺関節バロットメントテストの生体力学的研究
Authors: Onishi, Tadanobu
Omokawa, Shohei
Iida, Akio
Nakanishi, Yasuaki
Kira, Tsutomu
Moritomo, Hisao
Ruxasagluwang, Sompob
Kraisarin, Jirchart
Shimizu, Takamasa
Tanaka, Yasuhito
Keywords: biomechanics
distal radioulnar joint
ballottement test
human cadaver
Issue Date: May-2017
Publisher: Wiley
Citation: Journal of orthopaedic research Vol.35 No.5 p.1123-1127 (2017 May)
Abstract: We investigated the reliability and accuracy of the distal radioulnar joint (DRUJ) ballottement test using five fresh-frozen cadaver specimens in triangular fibrocartilage complex (TFCC)-intact, and TFCC-sectioned wrists. The humerus and proximal ulna were fixed. The ulna was allowed to translate in dorsopalmar directions without rotation, and the radius was allowed to move freely. Four sensors of a magnetic tracking system were attached to the radius and ulna, and the nails of each examiner's thumbs. Five examiners conducted the DRUJ ballottement test before and after TFCC sectioning. We used two techniques: With holding and without holding the carpal bones to the radius (holding and non-holding tests, respectively). We compared the magnitudes of bone-to-bone (absolute DRUJ) movement with that of the examiner's nail-to-nail (relative DRUJ) movement. The intrarater intraclass correlation coefficients (ICCs) were 0.92 (holding) and 0.94 (non-holding). The interrater ICCs were 0.84 (holding) and 0.75 (non-holding). Magnitudes of absolute and relative movements averaged 11.5 and 11.8 mm, respectively (p < 0.05). Before TFCC sectioning, the DRUJ movement during the holding and non-holding techniques averaged 9.8 and 10.8 mm, respectively (p < 0.05). The increase in DRUJ movement after TFCC sectioning was greater with the holding technique (average 2.3 mm) than with the non-holding technique (average 1.6 mm). The DRUJ ballottement test with magnetic markers is relatively accurate and reliable for detecting unstable joints. We recommend the holding technique for assessing DRUJ instability in clinical practice.
Description: 博士(医学)・甲第686号・平成30年6月27日
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
URI: http://hdl.handle.net/10564/3455
ISSN: 07360266
Academic Degrees and number: 24601A686
Degree-granting date: 2018-06-27
Degree name: 博士(医学)
Degree-granting institutions: 奈良県立医科大学
Appears in Collections:2018年度

Files in This Item:

File Description SizeFormat
01甲686本文の要旨.pdf甲686本文の要旨593.76 kBAdobe PDFView/Open
02甲686審査要旨.pdf甲686審査要旨1.7 MBAdobe PDFView/Open
03甲686本文.pdf甲686本文597.95 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback